A delayed self-heterodyne system for measuring laser diode linewidth, combining a SYCATUS test set with a Keysight X-Series signal analyzer. SYCATUS states a minimum measurable linewidth of 40 kHz.
The SYCATUS test set contains a delayed self-heterodyne interferometer followed by a high-gain linear optical receiver, with a polarization controller inside the interferometer to set the interference condition. The interferometer output is read by a Keysight X-Series signal analyzer, from which SYCATUS states 3 dB, 10 dB and 20 dB linewidth figures are obtained directly. Interferometer and optical receiver are housed in one box, and the delay fibre length, wavelength band and minimum linewidth are set by ordering option.
| Parameter | Value |
|---|---|
| Optical wavelength | 1520 to 1620 nm |
| Minimum measurable linewidth | 40 kHz |
| Optical input power range | -20 to +7 dBm |
| Frequency shift of interferometer, typ. | 100 MHz |
| Optical wavelength range options (datasheet) | 1520 - 1620 nm, 1260 - 1360 nm, or 1260 - 1620 nm nm |
| Minimum linewidth frequency options (datasheet) | 40 kHz or 10 kHz kHz |
| Delay fibre length of interferometer (datasheet) | 5 km or 20 km km |

Chromatic dispersion measurement system for optical fiber and cable manufacturing. Uses a temperature-stabilised solid-state monochromator with DSP-based detection.

Fiber curl measurement system that measures the natural, relaxed-state curl of an optical fiber using a self-referencing dual-beam laser method.
A 2U rack-mount controller that interrogates networks of FiberStrike fiber optic tamper switches and converts each switch state into a dry relay contact output. Intended for access-point security monitoring at manholes, hatchways and vaults.
Our application engineers will confirm specifications with the manufacturer and quote for your configuration.
Request Info